Durastar 28,000 BTU Cooling / 28,000 BTU Heating 23.5 SEER2 Three Zone Mini Split Condenser Unit
Model: DRA3U28M1B|Item: bci4476781
Details
Outdoor condenser unit only, indoor evaporator unit(s) required for proper functionality. For questions or assistance building a multi-zone system, please call (855) 484-3292 to speak to one of our experts.
Engineered for comfort, Durastar is backed by resilient technology and will withstand the test of time and nature's elements. Providing energy efficient, value-friendly HVAC equipment for every space, Durastar creates a comfortable environment for any homeowner. Durastar mini-splits are ideal for renovations, remodels and zone-specific heating and cooling needs.
Features:
- Included Base Pan Heater
- The outdoor unit features a defrost feature, which removes frost from the condenser coil in frigid conditions and perform reliably at lower temperatures.
- The outdoor unit features a defrost feature, which removes frost from the condenser coil in frigid conditions.
Product Technologies:
- Anti-Corrosive Fin Coating: Durastar condensers and indoor units feature Golden Fin Coating, an anti-corrosive fin coating to ensure the longevity, reliability and prevent corrosion this improves its durability.
- Quiet Operation: Both the outdoor and indoor units enjoy reduced electrical and mechanical sound thanks to their brushless direct current fan motors.
- Auto Changeover: Set it and forget it. With Durastar's Auto Changeover feature, you can set the temperature and it will automatically switch between heating and cooling to maintain your temperature.
- Anti-corrosive fin coating: Durastar condensers employ an anti-corrosive fin coating to ensure the longevity, reliability and prevent corrosion this improves its durability.
Specifications:
- Cooling BTU Capacity: 28000
- Heating BTU Capacity: 28000
- Zone Capacity: 3
- Cooling Area: 1300 Sq. Ft.
- Sound Level: 61 dB
- Minimum Outdoor Temperature for Heating: -13 F
- Minimum Outdoor Temperature for Cooling: 5 F
- Depth: 16-1/8"
- Height: 31-7/8"
- Width: 37-1/4"
- Recommended Breaker Size: 30 A
- Voltage: 208, 230V
Product Assurance:
- Performance and Efficiency:
- SEER: 22.5
- SEER2: 23.5
- HSPF: 10.2
- HSPF2: 9.2
- EER: 12
- Manufacturer Warranty: 10 Year Parts
Required Components:
- Disconnect Box and Electrical Whip Kit: The disconnect box and whip kit gives an easy way to connect your outdoor condenser to your fuse box
- Base Pan Heater: The base pan heater stops ice from building up on the outdoor unit, preventing performance degradation and potential damage
- Outdoor Condenser Plastic Pad (Optional): An outdoor condenser pad provides an even surface on which to place your outdoor condenser
- Wall Bracket (Optional): A wall bracket provides a way to mount your outdoor condenser off the ground to keep it clear it of debris
Dimensions and Measurements
CFM | 2129 |
Cooling Area | 1300 sq. ft. |
Depth (Condenser) | 16.125 in. |
Height (Condenser) | 31.875 in. |
Maximum Line Set Length | 197 ft. |
Product Weight | 139.8 lbs. |
Width (Condenser) | 37.25 in. |
Dimensions and Measurements
CFM | 2129 |
Cooling Area | 1300 sq. ft. |
Depth (Condenser) | 16.125 in. |
Height (Condenser) | 31.875 in. |
Maximum Line Set Length | 197 ft. |
Product Weight | 139.8 lbs. |
Width (Condenser) | 37.25 in. |
Included Components
Base Pan Heater Included | Yes |
Heater Included | Yes |
Included Components
Base Pan Heater Included | Yes |
Heater Included | Yes |
Characteristics and Features
Auto Restart | Yes |
Installation Type | Mini Split |
Refrigerant | R-410A |
Characteristics and Features
Auto Restart | Yes |
Installation Type | Mini Split |
Refrigerant | R-410A |
Electrical and Operational Information
Amperage | 30 |
Breaker Needs | 30 Amps |
Cooling BTU Capacity | 28000 |
dBA (High) | 61 |
EER | 12 |
Electrical Phases | 1 |
Frequency | 60 Hertz |
Heating BTU Capacity | 28000 |
Minimum Outdoor Temperature for Cooling | 5 °F |
Minimum Outdoor Temperature for Heating | -13 °F |
Power Source | Hardwired |
Voltage | 208, 230 |
Zone Capacity | 3 |
Electrical and Operational Information
Amperage | 30 |
Breaker Needs | 30 Amps |
Cooling BTU Capacity | 28000 |
dBA (High) | 61 |
EER | 12 |
Electrical Phases | 1 |
Frequency | 60 Hertz |
Heating BTU Capacity | 28000 |
Minimum Outdoor Temperature for Cooling | 5 °F |
Minimum Outdoor Temperature for Heating | -13 °F |
Power Source | Hardwired |
Voltage | 208, 230 |
Zone Capacity | 3 |
Warranty and Product Information
Certifications | AHRI, CSA, UL |
Energy Star | Yes |
HSPF | 10.2 |
HSPF2 | 9.2 |
Manufacturer Warranty | 10 Year Parts |
SEER Cooling | 22.5 |
SEER2 | 23.5 |
Warranty and Product Information
Certifications | AHRI, CSA, UL |
Energy Star | Yes |
HSPF | 10.2 |
HSPF2 | 9.2 |
Manufacturer Warranty | 10 Year Parts |
SEER Cooling | 22.5 |
SEER2 | 23.5 |