Reznor 150,000 BTU - Power Vent Natural Gas Unit Heater - Low Static Axial Fan - Aluminized Heat Exchanger
Model: UDX-150|Item: bci4800408
Details
Reznor UDX gas-fired unit heaters are great for space heating applications. These units are power vented to eliminate heat losses up the flue pipe. The UDX uses an axial propellor fan for air circulation and is available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input and are approved for installation in the United States and Canada by ETL. UDX unit heaters feature a two-tone black and white powder coated, scratch-resistant paint scheme. Each unit has clean rounded corners and edges with no visible screws or fasteners.
Reznor UDX-150 Features:
- TCORE2 titanium stabilized aluminized steel heat exchanger
- Multi-try, direct spark ignition with time lockout
- Vibration/noise isolated fan and venter motors designed for low noise operation
- External status indicating LED that blinks if there is a problem that needs service
- 7-segment display board that shows fault code for quick and easy troubleshooting
- Optional integrated downturn nozzle and integrated vertical louvers
- Sizes 30-400 certified for commercial/industrial heating applications
- Sizes 30-125 approved for use in residential garages and workshops
General Information:
- Product Category: Unit Heater
- Fuel Type: Natural Gas
- Vent Type: Power Vent
- Installation Type: Suspended
Performance:
- BTU Heating: 150,000
- Maximum BTU Input: 150,000
- Maximum Air Flow: 1921 CFM
Electrical Data:
- Voltage: 115V
- Electrical Phases: 1
Dimensions:
- Pipe Inside Diameter: 4" and 6"
- Gas Connection Size: 1/2"
- Height: 20-1/8"
- Width: 38-3/16"
- Depth: 48-7/16"
- Product Weight: 178 lbs
Product Assurance:
- Certifications: ANSI
- Made in America
- Warranty: 10 Year Heat Exchanger and 5 Year Parts
Manufacturer Resources
Installation SheetBrochureUnit Heater CatalogVenting InstructionsSpecification SheetWarrantyDimensions and Measurements
CFM | 1921 |
Depth | 48.4375 in. |
Gas Connection | 1/2" |
Height | 20.125 in. |
Nominal Depth | 49 in. |
Nominal Height | 21 in. |
Nominal Width | 39 in. |
Pipe Inside Diameter | 4, 6 in. |
Product Weight | 178 lbs. |
Width | 38.1875 in. |
Dimensions and Measurements
CFM | 1921 |
Depth | 48.4375 in. |
Gas Connection | 1/2" |
Height | 20.125 in. |
Nominal Depth | 49 in. |
Nominal Height | 21 in. |
Nominal Width | 39 in. |
Pipe Inside Diameter | 4, 6 in. |
Product Weight | 178 lbs. |
Width | 38.1875 in. |
Characteristics and Features
Installation Type | Suspended |
Vent Type | Power Vent |
Characteristics and Features
Installation Type | Suspended |
Vent Type | Power Vent |
Electrical and Operational Information
BTU Heating | 150000 |
Electrical Phases | 1 |
Fuel Type | Natural Gas |
Max BTU Input | 150000 |
Voltage | 115 |
Electrical and Operational Information
BTU Heating | 150000 |
Electrical Phases | 1 |
Fuel Type | Natural Gas |
Max BTU Input | 150000 |
Voltage | 115 |
Warranty and Product Information
Certifications | ANSI |
Country Of Origin | USA |
Made in America | Yes |
Manufacturer Warranty | 10 Year Heat Exchanger, 5 Year Parts |
Warranty and Product Information
Certifications | ANSI |
Country Of Origin | USA |
Made in America | Yes |
Manufacturer Warranty | 10 Year Heat Exchanger, 5 Year Parts |