Revolv 45,000 BTU Single Stage Multi-Speed Natural Gas Furnace - 95% AFUE - No Coil Cabinet
Model: MG2R-045FA|Item: bci4797536
Details
Revolv is dedicated to bringing efficient comfort to the manufactured and mobile home market. The MG2R is a downflow gas furnace capable of providing 43,000 BTU of heating at 95% AFUE. Designed for easy installation in a variety of manufactured and modular homes, the MG2R features a small footprint and is HUD-compliant. The MG2R includes an efficient ECM blower motor, allowing for powerful airflow at the fraction of the energy cost as a traditional PSC motor. With durable construction and a dependable warranty, the Revolv MG2R is a reliable solution for your manufactured home heating needs.
Product Information:
- High Efficiency Heating
- Revolv MG2R furnaces are designed to save you money. Sporting a 95% AFUE efficiency rating, Revolv's high efficiency line will provide heat while keeping money in your pocket. ECM Motor
- The MG2R includes a high efficiency, multi-speed ECM blower motor, granting powerful CFM ratings at the fraction of the energy costs of traditional PSC motors. Category IV Venting
- The MG2R's efficient technology allows for vertical or horizontal direct venting using approved non-metallic components for application flexibility. Quick LP Conversion
- An easy-access gas valve regulator, manifold and included LP orifices make propane conversion a breeze.
General Information:
- Fuel Type: Natural Gas
- Heater Type: Furnace
- Vent Type: Direct Vent
- Stage: Single Stage
- Blower Motor Type: Multi Speed Electronically Commutated Motor (ECM)
- Airflow Orientation: Downflow
Performance:
- AFUE Rating 95%
- Heating BTU: 45,000
- High Fire Input: 45,000
- High Fire Output: 42,750
- NOx Emissions: Standard
Electrical Data:
- Voltage: 120V
- Electrical Phases: 1
- Frequency: 60 Hz
- Breaker Needs: 20 Amps
Dimensions:
- Gas Connection Size: 1/2"
- Height: 56"
- Width: 19-3/4"
- Depth: 23-3/4"
Product Assurance:
- Certifications: AHRI
- AHRI Reference Number: 204600307
- 10 Year Heat Exchanger, 2 Year Parts Manufacturer Warranty
Dimensions and Measurements
Cabinet Width | 19.75 in. |
CFM | 1605 |
Depth | 23.75 in. |
Gas Connection | 1/2" |
Height | 56 in. |
Nominal Depth | 24 in. |
Nominal Height | 56 in. |
Nominal Width | 20 in. |
Pipe Inside Diameter | 2, 3 in. |
Width | 19.75 in. |
Dimensions and Measurements
Cabinet Width | 19.75 in. |
CFM | 1605 |
Depth | 23.75 in. |
Gas Connection | 1/2" |
Height | 56 in. |
Nominal Depth | 24 in. |
Nominal Height | 56 in. |
Nominal Width | 20 in. |
Pipe Inside Diameter | 2, 3 in. |
Width | 19.75 in. |
Included Components
Blower | Yes |
Vent Free | No |
Included Components
Blower | Yes |
Vent Free | No |
Characteristics and Features
Airflow Orientation | Downflow |
Blower Type | Multi Speed |
Heater Type | Furnace |
Motor Type | Electronically Commutated Motor (ECM) |
NG Conversion | Yes |
Vent Type | Direct Vent |
Characteristics and Features
Airflow Orientation | Downflow |
Blower Type | Multi Speed |
Heater Type | Furnace |
Motor Type | Electronically Commutated Motor (ECM) |
NG Conversion | Yes |
Vent Type | Direct Vent |
Electrical and Operational Information
Breaker Needs | 20 Amps |
BTU Heating | 45000 |
Electrical Phases | 1 |
Frequency | 60 Hertz |
Fuel Type | Natural Gas |
High Fire Input | 45000 |
High Fire Output | 42750 |
Stages | Single Stage |
Voltage | 120 |
Electrical and Operational Information
Breaker Needs | 20 Amps |
BTU Heating | 45000 |
Electrical Phases | 1 |
Frequency | 60 Hertz |
Fuel Type | Natural Gas |
High Fire Input | 45000 |
High Fire Output | 42750 |
Stages | Single Stage |
Voltage | 120 |
Warranty and Product Information
AFUE Rating | 95 % |
AHRI Reference Number | 204600307 |
Certifications | AHRI |
Manufacturer Warranty | 10 Year Heat Exchanger, 2 Year Parts |
Mobile Home Approved | Yes |
NOx Emissions | Standard |
Warranty and Product Information
AFUE Rating | 95 % |
AHRI Reference Number | 204600307 |
Certifications | AHRI |
Manufacturer Warranty | 10 Year Heat Exchanger, 2 Year Parts |
Mobile Home Approved | Yes |
NOx Emissions | Standard |