Mitsubishi M Series 9K BTU Cooling / 9K BTU Heating 22.4 SEER One Zone Ceiling Cassette Mini Split Package
Model: SL-KF09NA.TH|Item: bci4685871
Details
For questions or assistance, please call (855) 484-3292 to speak to one of our experts.
For over 50 years, Mitsubishi has remained at the forefront of the mini split industry thanks to their dedication to providing efficient, user-friendly comfort solutions. The SL-KF09NA is a packaged single zone heat pump mini split system designed to bring discreet heating and cooling to any room in your home. Featuring Mitsubishi's 3D i-see Sensor,™ the indoor cassette unit thermally scans for warm and cold spots so conditioned air can be directed effectively. The outdoor condenser uses some of the most advanced technology available to modulate temperature without energy-wasting overshoots and short-cycling associated with simpler systems. With an included wireless remote controller, this system is the perfect combination of convenience and comfort for any application.
Features:
- Precision Temperature Control Technology: The SUZ-KA outdoor condenser uses inverter technology when cooling or heating your home. Rather than simply turning on and off, the outdoor condenser adjusts output based on temperature demand, resulting in efficient and precise heating and cooling.
- 3D i-see Sensor™: The SLZ-KF cassette unit includes an advanced thermal sensor that scans the room for hot and cold spots as well as occupancy. Using this information, the cassette unit can be programmed to direct airflow to certain areas of the zone in specific scenarios.
- Hot-Start: Mitsubishi's hot start technology prevents cold drafts by delaying fan operation until the heat exchanger has warmed up.
- Dehumidification: When the indoor unit runs in dry mode, the coil's temperature stays just below the dew point of the return air, removing unwanted moisture. This improves comfort and reduces the chance of mold growth and other property damage in the conditioned space.
- Vane Control: Optimal air flow can be achieved with the SLZ-KF thanks to the individual vane control option. This function provides access to an auto mode and a swing mode.
- Condensate Removal System: The SLZ-KF contains an internal drain mechanism capable of lifting condensate 33". This simplifies installation and prevents condensate overflow, which can damage or destroy your property.
- Advanced Remote Controller: The MHK1 wireless remote controller kit supports dual set point control and multiple scheduling options. The Optimal Start function learns how quickly your zone is cooled and heated to ensure the zone is always the right temperature at the right time.
Product Assurance:
- Certifications:
- AHRI
- ETL
- Performance and Efficiency:
- SEER: 22.4
- HSPF: 12.2
- EER: 13.4
- Manufacturer Warranty: 5 Year Parts
Required Components:
- Line Set: Line set tubing transfers refrigerant between your outdoor condenser and indoor units
- Drain Line: The drain line removes the condensate from your system. It connects your system to the drain location of your choosing
- Connecting Cable: The connecting cable provides power to your indoor units from your outdoor condenser
- Disconnect Box and Electrical Whip Kit: The disconnect box and whip kit gives an easy way to connect your outdoor condenser to your fuse box
- Base Pan Heater (Optional): The base pan heater stops ice from building up on the outdoor unit, preventing performance degradation and potential damage
- Outdoor Condenser Plastic Pad (Optional): An outdoor condenser pad provides an even surface on which to place your outdoor condenser
- Wall Bracket (Optional): A wall bracket provides a way to mount your outdoor condenser off the ground to keep it clear it of debris
Specifications:
MHK2
- Width: 4-1/16"
- Length: 4-1/16"
- Depth: 1-1/16"
SLP-18FAEU
- Width: 24-5/8"
- Length: 3/8"
- Depth: 24-5/8"
- Product Weight: 5.3 lbs.
SUZ-KA09NA2.MX
- Cooling BTU Capacity: 9000
- Zone Capacity: 1
- Sound Level: 48 to 50 dB
- Low Ambient Heating: Yes
- Minimum Outdoor Temperature for Heating: -4 F
- Minimum Outdoor Temperature for Cooling: 14 F
- Liquid Line Connection Size: 1/4" Inch
- Gas Line Connection Size: 3/8" Inch
- Depth: 11-1/4"
- Height: 21-5/8"
- Width: 31-1/2"
- Recommended Breaker Size: 15 A
- Amperage: 9 A
- Voltage: 208, 230V
SLZ-KF09NA.TH-NG
- Zone Cooling BTU: 9000
- Zone Heating BTU: 11000
- Sound Level: 25 to 31 dB
- Liquid Line Connection Size: 1/4" Inch
- Gas Line Connection Size: 3/8" Inch
- Depth: 22-7/16"
- Height: 9-1/2"
- Width: 22-7/16"
- Voltage: 208, 230V
Dimensions and Measurements
CFM | 335, 207 |
Depth (Condenser) | 11.25 in. |
Depth (Indoor Unit) | 22.4375 in. |
Gas Connection | 3/8" |
Height (Condenser) | 21.625 in. |
Height (Indoor Unit) | 9.5 in. |
Liquid Line Connection Size | 1/4" |
Maximum Line Set Length | 65 ft. |
Width (Condenser) | 31.5 in. |
Width (Indoor Unit) | 22.4375 in. |
Dimensions and Measurements
CFM | 335, 207 |
Depth (Condenser) | 11.25 in. |
Depth (Indoor Unit) | 22.4375 in. |
Gas Connection | 3/8" |
Height (Condenser) | 21.625 in. |
Height (Indoor Unit) | 9.5 in. |
Liquid Line Connection Size | 1/4" |
Maximum Line Set Length | 65 ft. |
Width (Condenser) | 31.5 in. |
Width (Indoor Unit) | 22.4375 in. |
Included Components
Branch Box Required | No |
Heater Included | Yes |
Includes Remote | No |
Included Components
Branch Box Required | No |
Heater Included | Yes |
Includes Remote | No |
Characteristics and Features
Control Type | Remote |
Indoor Unit Type | Ceiling Cassette |
Installation Type | Mini Split |
Low Ambient Heating | Yes |
Refrigerant | R410A |
Characteristics and Features
Control Type | Remote |
Indoor Unit Type | Ceiling Cassette |
Installation Type | Mini Split |
Low Ambient Heating | Yes |
Refrigerant | R410A |
Electrical and Operational Information
Amperage | 9 |
Breaker Needs | 15 Amps |
Cooling BTU Capacity | 9000 |
Cooling Power Input | 670 |
dBA (High) | 50 |
dBA (Low) | 25 |
EER | 13.4 |
Electrical Phases | 1 |
Frequency | 60 Hertz |
Heating BTU Capacity | 9000 |
Heating Power Input | 810 |
Minimum Outdoor Temperature for Cooling | 14 °F |
Minimum Outdoor Temperature for Heating | -4 °F |
Number of Zones | 1 |
Power Source | Hardwired |
Voltage | 208, 230 |
Zone Capacity | 1 |
Zone Cooling BTU | 9000 |
Zone Heating BTU | 11000 |
Electrical and Operational Information
Amperage | 9 |
Breaker Needs | 15 Amps |
Cooling BTU Capacity | 9000 |
Cooling Power Input | 670 |
dBA (High) | 50 |
dBA (Low) | 25 |
EER | 13.4 |
Electrical Phases | 1 |
Frequency | 60 Hertz |
Heating BTU Capacity | 9000 |
Heating Power Input | 810 |
Minimum Outdoor Temperature for Cooling | 14 °F |
Minimum Outdoor Temperature for Heating | -4 °F |
Number of Zones | 1 |
Power Source | Hardwired |
Voltage | 208, 230 |
Zone Capacity | 1 |
Zone Cooling BTU | 9000 |
Zone Heating BTU | 11000 |
Warranty and Product Information
AHRI Reference Number | 202392021 |
Certifications | AHRI, ETL |
DOE Regional Compliance | Nationwide |
HSPF | 12.2 |
Manufacturer Warranty | 5 Year Parts |
SEER Cooling | 22.4 |
Warranty and Product Information
AHRI Reference Number | 202392021 |
Certifications | AHRI, ETL |
DOE Regional Compliance | Nationwide |
HSPF | 12.2 |
Manufacturer Warranty | 5 Year Parts |
SEER Cooling | 22.4 |