LG 9K BTU Cooling / 10.1K BTU Heating 18.5 SEER2 One Zone Floor Console Mini Split Package
Model: LQ090HV|Item: bci4702186
This package includes the following items
Details
For questions or assistance, please call (855) 484-3292 to speak to one of our experts.
LG's devotion to providing efficient ductless solutions can be seen across their entire catalog. LG's Low Wall Console is perfect for areas where you don't have the ceiling height or wall space to allow for a wall mounted unit. This ductless heat pump system features an easy installation process, a full-featured wireless handheld remote controller, and several operation modes aimed at increasing power and efficiency. Over the years, LG has strived to meet the demand for high quality air conditioning solutions with greater energy efficiency, helping the environment while also reducing electricity costs for consumers.
Special Features:
- Inverter Technology: An electronic expansion valve and a variable speed condenser compressor carefully regulate the refrigerant flow, reducing energy consumption and allowing for consistent, accurate temperatures without overshooting or short-cycling.
- Gold Fin Protection: To ensure the reliability and longevity of the condenser's heat exchanger, LG employs a Gold Fin coating that prevents corrosion and improves durability.
- Quiet Design: LG uses advanced components to ensure that their systems are as quiet as possible. In the outdoor condenser, a twin rotary compressor reduces vibration to limit noise while both the outdoor and indoor units utilize brushless fan motors.
- Jet Cool: This system features a Jet Cool operation mode for rapid cooling. In this mode, the indoor unit observes a set point of 64 degrees Fahrenheit and the fan operates at maximum speed for 30 minutes to quickly cool your zone.
- Sleep Mode: With the sleep mode and timer functions, you can set the indoor units to save energy at night. Sleep mode will incrementally increase temperature for an hour before the timer function automatically deactivates the unit.
- Improved Air Quality: The low wall consoles feature an anti-fungal filter to keep your air clean. This filter captures contaminants like dust and bacteria and is washable to ensure long term air quality.
Product Assurance:
- Certifications:
- ETL
- ISO
- Performance and Efficiency:
- SEER: 18.5
- SEER2: 18.5
- HSPF: 9.8
- HSPF2: 9
- EER: 12.5
- Manufacturer Warranty: 5 Year Limited
Required Components:
- Line Set: Line set tubing transfers refrigerant between your outdoor condenser and indoor units
- Drain Line: The drain line removes the condensate from your system. It connects your system to the drain location of your choosing
- Connecting Cable: The connecting cable provides power to your indoor units from your outdoor condenser
- Disconnect Box and Electrical Whip Kit: The disconnect box and whip kit gives an easy way to connect your outdoor condenser to your fuse box
- Base Pan Heater (Optional): The base pan heater stops ice from building up on the outdoor unit, preventing performance degradation and potential damage
- Outdoor Condenser Plastic Pad (Optional): An outdoor condenser pad provides an even surface on which to place your outdoor condenser
- Wall Bracket (Optional): A wall bracket provides a way to mount your outdoor condenser off the ground to keep it clear it of debris
Specifications:
LUU090HV
- Cooling BTU Capacity: 9000
- Sound Level: 51 dB
- Low Ambient Heating: Yes
- Minimum Outdoor Temperature for Heating: -4 F
- Minimum Outdoor Temperature for Cooling: 0 F
- Liquid Line Connection Size: 1/4" Inch
- Depth: 13-7/8"
- Height: 21-1/2"
- Width: 34"
- Recommended Breaker Size: 15 A
- Voltage: 208, 230V
LQN090HV4
- Zone Cooling BTU: 9000
- Zone Heating BTU: 11000
- Cooling Area: 400 Sq. Ft.
- Sound Level: 27 to 38 dB
- Liquid Line Connection Size: 1/4" Inch
- Gas Line Connection Size: 3/8" Inch
- Depth: 8-1/4"
- Height: 23-5/8"
- Width: 27-9/16"
- Voltage: 208, 230V
Dimensions and Measurements
CFM | 247, 353 |
Cooling Area | 550 sq. ft. |
Depth (Condenser) | 11.531 in. |
Depth (Indoor Unit) | 27.563 in. |
Gas Connection | 3/8" |
Height (Condenser) | 25.594 in. |
Height (Indoor Unit) | 7.469 in. |
Liquid Line Connection Size | 1/4" |
Maximum Line Set Length | 230 ft. |
Product Weight | 252.83 lbs. |
Width (Condenser) | 34.25 in. |
Width (Indoor Unit) | 38.344 in. |
Dimensions and Measurements
CFM | 247, 353 |
Cooling Area | 550 sq. ft. |
Depth (Condenser) | 11.531 in. |
Depth (Indoor Unit) | 27.563 in. |
Gas Connection | 3/8" |
Height (Condenser) | 25.594 in. |
Height (Indoor Unit) | 7.469 in. |
Liquid Line Connection Size | 1/4" |
Maximum Line Set Length | 230 ft. |
Product Weight | 252.83 lbs. |
Width (Condenser) | 34.25 in. |
Width (Indoor Unit) | 38.344 in. |
Included Components
Heater Included | Yes |
Includes Remote | Yes |
Includes Thermostat | Yes |
Included Components
Heater Included | Yes |
Includes Remote | Yes |
Includes Thermostat | Yes |
Characteristics and Features
Auto Restart | Yes |
Control Type | Remote |
Indoor Unit Type | Floor Console |
Installation Type | Mini Split |
Low Ambient Heating | Yes |
Refrigerant | R-410A |
Wireless Communication | WiFi |
Characteristics and Features
Auto Restart | Yes |
Control Type | Remote |
Indoor Unit Type | Floor Console |
Installation Type | Mini Split |
Low Ambient Heating | Yes |
Refrigerant | R-410A |
Wireless Communication | WiFi |
Electrical and Operational Information
Amperage | 20 |
Auto Shut Off | Yes |
Breaker Needs | 20 Amps |
Cooling BTU Capacity | 9000 |
Cooling Power Input | 1.48 |
dBA (High) | 54 |
dBA (Low) | 27 |
EER | 12.5 |
Electrical Phases | 1 |
Fan Speeds | 3 |
Frequency | 60 Hertz |
Heating BTU Capacity | 10100 |
Heating Power Input | 1.8 |
Minimum Outdoor Temperature for Cooling | 14 °F |
Minimum Outdoor Temperature for Heating | -4 °F |
Number of Zones | 1 |
Power Source | Hardwired |
Voltage | 208 |
Zone Capacity | 3 |
Zone Cooling BTU | 12000 |
Zone Heating BTU | 13800 |
Electrical and Operational Information
Amperage | 20 |
Auto Shut Off | Yes |
Breaker Needs | 20 Amps |
Cooling BTU Capacity | 9000 |
Cooling Power Input | 1.48 |
dBA (High) | 54 |
dBA (Low) | 27 |
EER | 12.5 |
Electrical Phases | 1 |
Fan Speeds | 3 |
Frequency | 60 Hertz |
Heating BTU Capacity | 10100 |
Heating Power Input | 1.8 |
Minimum Outdoor Temperature for Cooling | 14 °F |
Minimum Outdoor Temperature for Heating | -4 °F |
Number of Zones | 1 |
Power Source | Hardwired |
Voltage | 208 |
Zone Capacity | 3 |
Zone Cooling BTU | 12000 |
Zone Heating BTU | 13800 |
Warranty and Product Information
AHRI Reference Number | 208131887 |
Approved for Commercial Use | Yes |
Certifications | ETL, ISO |
Collection | Multi F |
Country Of Origin | South Korea |
DOE Regional Compliance | Nationwide |
Energy Star | Yes |
HSPF | 9.8 |
HSPF2 | 9 |
Manufacturer Warranty | 5 Year Limited |
SEER Cooling | 18.5 |
SEER2 | 18.5 |
Warranty and Product Information
AHRI Reference Number | 208131887 |
Approved for Commercial Use | Yes |
Certifications | ETL, ISO |
Collection | Multi F |
Country Of Origin | South Korea |
DOE Regional Compliance | Nationwide |
Energy Star | Yes |
HSPF | 9.8 |
HSPF2 | 9 |
Manufacturer Warranty | 5 Year Limited |
SEER Cooling | 18.5 |
SEER2 | 18.5 |