LG Multi F Series 36K BTU Cooling / 36K BTU Heating 21.5 SEER2 Four Zone Ceiling Cassette Mini Split Package with (4) 9k BTU Indoor Units
Model: L4H36C09090909-A|Item: bci3316950
This package includes the following items
Details
For questions or assistance, please call (855) 484-3292 to speak to one of our experts.
LG's devotion to providing efficient ductless solutions can be seen across the Multi F line. This ceiling cassette ductless heat pump system pairs a powerful LMU363HV outdoor condenser with four ceiling cassette indoor units. LG's Multi F ceiling cassette indoor units feature four air outlets which allow them to provide consistent air flow to the furthest reaches of large rooms. In addition to providing excellent coverage, the ceiling cassette indoor units also feature an exceptionally low profile. When installed, a grille less than 1" thick is the only visible clue that your room is receiving efficient heating and cooling from a ductless heat pump system.
Features:
- When the hot start function is enabled on a mini split indoor unit, the fan will not engage until the outdoor condenser has had the opportunity to warm the indoor coil. This prevents the unit from blowing cold air during heating operations.
- LG cassette units feature designated cutouts for a branch duct, giving you the ability to duct up to 1/2 of the unit's airflow capacity to adjacent spaces.
Special Features:
- Inverter Technology: LG's outdoor condensers are designed with efficient inverter technology. An electronic expansion valve and a variable speed compressor carefully regulate the refrigerant flow, reducing energy consumption and allowing for consistent, accurate temperatures.
- Gold Fin Protection: To ensure the reliability and longevity of the LMU363HV's heat exchanger, LG employs a Gold Fin coating that prevents corrosion and improves durability.
- Quiet Design: Thanks to brushless fan motors, both the outdoor and indoor units in this system produce less mechanical and electrical noise. A twin rotary compressor in the outdoor unit also limits vibration noise.
- Air Flow Options: There are three automated air flow options with LG's ceiling cassette indoor units: swing mode, Chaos Wind, and Swirl Wind mode. Any of these modes can be activated to provide optimal circulation specific to your home.
- Jet Cool: These LG mini split indoor units feature a Jet Cool operation mode for rapid cooling. In this mode, an indoor unit observes a set point of 64 degrees Fahrenheit while the fan operates at maximum speed for 30 minutes to quickly cool your zone.
- Automated Operation: Auto operation mode continually compares your zones' current and desired temperatures and uses that data to intelligently adjust fan speed and refrigerant flow to provide optimal comfort.
- Sleep Mode: With the sleep mode and timer functions, you can set the indoor units to save energy at night. Sleep mode will incrementally adjust temperatures for an hour before the timer function automatically deactivates the units.
- Condensate Protection: Condensate overflow can damage your indoor unit and your home. Internal condensate pumps with 27.5" of lift protect these indoor units through reliable, effective condensate removal.
- Improved Air Quality: These mini split indoor units include anti-fungal filters to keep your air clean. These filters capture contaminants like dust and bacteria, and they are washable to ensure long term air quality.
- Dehumidify: LG's multi-zone indoor units include a dehumidifying operation mode. In this mode, the units' internal sensors monitor temperature and modify the set point and fan speed to remove moisture from the air.
Product Assurance:
- Certifications:
- AHRI
- ISO
- Performance and Efficiency:
- SEER: 22
- SEER2: 21.5
- HSPF: 10
- HSPF2: 9
- EER: 13
- Manufacturer Warranty: 5 Year Limited
Required Components:
- Line Set: Line set tubing transfers refrigerant between your outdoor condenser and indoor units
- Drain Line: The drain line removes the condensate from your system. It connects your system to the drain location of your choosing
- Connecting Cable: The connecting cable provides power to your indoor units from your outdoor condenser
- Disconnect Box and Electrical Whip Kit: The disconnect box and whip kit gives an easy way to connect your outdoor condenser to your fuse box
- Base Pan Heater (Optional): The base pan heater stops ice from building up on the outdoor unit, preventing performance degradation and potential damage
- Outdoor Condenser Plastic Pad (Optional): An outdoor condenser pad provides an even surface on which to place your outdoor condenser
- Wall Bracket (Optional): A wall bracket provides a way to mount your outdoor condenser off the ground to keep it clear it of debris
Recommended Components:
- Recommended line set sizes for indoor unit connectivity:
- LCN097HV4-NOGRILLE: 1/4" x 3/8" Line Set (Qty 4)
Specifications:
LMU363HV
- Cooling BTU Capacity: 36000
- Heating BTU Capacity: 36000
- Zone Capacity: 4
- Sound Level: 54 dB
- Low Ambient Heating: Yes
- Minimum Outdoor Temperature for Heating: -4 F
- Minimum Outdoor Temperature for Cooling: 14 F
- Depth: 15-1/2"
- Height: 32-7/8"
- Width: 37-3/8"
- Recommended Breaker Size: 25 A
- Voltage: 208, 230V
PT-QAGW0 (x4)
- Type: Grilles
- Product Category: Mini Split Air Conditioner Accessory
- Width: 24-3/8"
- Length: 24-3/8
- Depth: 1-3/8"
LCN098HV4-NG (x4)
- Zone Cooling BTU: 9000
- Zone Heating BTU: 10400
- Cooling Area: 400 Sq. Ft.
- Sound Level: 30 to 36 dB
- Liquid Line Connection Size: 1/4" Inch
- Gas Line Connection Size: 3/8" Inch
- Depth: 22-7/16"
- Height: 8-7/16"
- Width: 22-7/16"
- Voltage: 208, 230V
Dimensions and Measurements
CFM | 300, 230 |
Cooling Area | 400 sq. ft. |
Depth (Condenser) | 15.5 in. |
Depth (Indoor Unit) | 22.4375 in. |
Gas Connection | 3/8" |
Height (Condenser) | 32.844 in. |
Height (Indoor Unit) | 8.4375 in. |
Liquid Line Connection Size | 1/4" |
Maximum Line Set Length | 246.1 ft. |
Product Weight | 455.9 lbs. |
Width (Condenser) | 37.406 in. |
Width (Indoor Unit) | 22.4375 in. |
Dimensions and Measurements
CFM | 300, 230 |
Cooling Area | 400 sq. ft. |
Depth (Condenser) | 15.5 in. |
Depth (Indoor Unit) | 22.4375 in. |
Gas Connection | 3/8" |
Height (Condenser) | 32.844 in. |
Height (Indoor Unit) | 8.4375 in. |
Liquid Line Connection Size | 1/4" |
Maximum Line Set Length | 246.1 ft. |
Product Weight | 455.9 lbs. |
Width (Condenser) | 37.406 in. |
Width (Indoor Unit) | 22.4375 in. |
Included Components
Branch Box Required | No |
Heater Included | Yes |
Includes Remote | Yes |
Includes Thermostat | Yes |
Includes Timer | Yes |
Line Set Included | No |
Included Components
Branch Box Required | No |
Heater Included | Yes |
Includes Remote | Yes |
Includes Thermostat | Yes |
Includes Timer | Yes |
Line Set Included | No |
Characteristics and Features
Auto Restart | Yes |
Control Type | Remote |
Indoor Unit Type | Ceiling Cassette |
Installation Type | Mini Split |
Low Ambient Heating | Yes |
Refrigerant | R-410A |
Wireless Communication | WiFi |
Characteristics and Features
Auto Restart | Yes |
Control Type | Remote |
Indoor Unit Type | Ceiling Cassette |
Installation Type | Mini Split |
Low Ambient Heating | Yes |
Refrigerant | R-410A |
Wireless Communication | WiFi |
Electrical and Operational Information
Amperage | 25 |
Auto Shut Off | Yes |
Breaker Needs | 25 Amps |
Cooling BTU Capacity | 36000 |
Cooling Power Input | 2461 |
dBA (High) | 54 |
dBA (Low) | 30 |
EER | 13 |
Electrical Phases | 1 |
Fan Speeds | 3 |
Frequency | 60 Hertz |
Heating BTU Capacity | 36000 |
Heating Power Input | 2740 |
Minimum Outdoor Temperature for Cooling | 14 °F |
Minimum Outdoor Temperature for Heating | -4 °F |
Number of Zones | 4 |
Power Source | Hardwired |
Voltage | 208 |
Zone Capacity | 4 |
Zone Cooling BTU | 9000 |
Zone Heating BTU | 10400 |
Electrical and Operational Information
Amperage | 25 |
Auto Shut Off | Yes |
Breaker Needs | 25 Amps |
Cooling BTU Capacity | 36000 |
Cooling Power Input | 2461 |
dBA (High) | 54 |
dBA (Low) | 30 |
EER | 13 |
Electrical Phases | 1 |
Fan Speeds | 3 |
Frequency | 60 Hertz |
Heating BTU Capacity | 36000 |
Heating Power Input | 2740 |
Minimum Outdoor Temperature for Cooling | 14 °F |
Minimum Outdoor Temperature for Heating | -4 °F |
Number of Zones | 4 |
Power Source | Hardwired |
Voltage | 208 |
Zone Capacity | 4 |
Zone Cooling BTU | 9000 |
Zone Heating BTU | 10400 |
Warranty and Product Information
AHRI Reference Number | 208131890 |
Approved for Commercial Use | Yes |
Certifications | AHRI, ISO |
Collection | Multi F |
DOE Regional Compliance | Nationwide |
Energy Star | Yes |
HSPF | 10 |
HSPF2 | 9 |
Manufacturer Warranty | 5 Year Limited |
SEER Cooling | 22 |
SEER2 | 21.5 |
Warranty and Product Information
AHRI Reference Number | 208131890 |
Approved for Commercial Use | Yes |
Certifications | AHRI, ISO |
Collection | Multi F |
DOE Regional Compliance | Nationwide |
Energy Star | Yes |
HSPF | 10 |
HSPF2 | 9 |
Manufacturer Warranty | 5 Year Limited |
SEER Cooling | 22 |
SEER2 | 21.5 |