Skip to main content
LG
N/A
Alternate Image
Alternate Image
Alternate Image
Alternate Image
N/A
Alternate Image
Alternate Image
Alternate Image
Alternate Image

LG Multi F Series 36K BTU Cooling / 36K BTU Heating 21.5 SEER2 Four Zone Ceiling Cassette Mini Split Package with (4) 9k BTU Indoor Units

Model: L4H36C09090909-A
|
Item: bci3316950

$6,170.25
Special Order
placeholder
Free Shipping!
Leaves the Warehouse in 6 to 11 weeks
-
Return & Shipping Details

Details

Please note: Mini splits must be installed by a professional according to your local codes. Any mini split installed otherwise will void any manufacturer warranty.

For questions or assistance, please call (855) 484-3292 to speak to one of our experts.

LG's devotion to providing efficient ductless solutions can be seen across the Multi F line. This ceiling cassette ductless heat pump system pairs a powerful LMU363HV outdoor condenser with four ceiling cassette indoor units. LG's Multi F ceiling cassette indoor units feature four air outlets which allow them to provide consistent air flow to the furthest reaches of large rooms. In addition to providing excellent coverage, the ceiling cassette indoor units also feature an exceptionally low profile. When installed, a grille less than 1" thick is the only visible clue that your room is receiving efficient heating and cooling from a ductless heat pump system.

Features:

  • When the hot start function is enabled on a mini split indoor unit, the fan will not engage until the outdoor condenser has had the opportunity to warm the indoor coil. This prevents the unit from blowing cold air during heating operations.
  • LG cassette units feature designated cutouts for a branch duct, giving you the ability to duct up to 1/2 of the unit's airflow capacity to adjacent spaces.

Special Features:

  • Inverter Technology: LG's outdoor condensers are designed with efficient inverter technology. An electronic expansion valve and a variable speed compressor carefully regulate the refrigerant flow, reducing energy consumption and allowing for consistent, accurate temperatures.
  • Gold Fin Protection: To ensure the reliability and longevity of the LMU363HV's heat exchanger, LG employs a Gold Fin coating that prevents corrosion and improves durability.
  • Quiet Design: Thanks to brushless fan motors, both the outdoor and indoor units in this system produce less mechanical and electrical noise. A twin rotary compressor in the outdoor unit also limits vibration noise.
  • Air Flow Options: There are three automated air flow options with LG's ceiling cassette indoor units: swing mode, Chaos Wind, and Swirl Wind mode. Any of these modes can be activated to provide optimal circulation specific to your home.
  • Jet Cool: These LG mini split indoor units feature a Jet Cool operation mode for rapid cooling. In this mode, an indoor unit observes a set point of 64 degrees Fahrenheit while the fan operates at maximum speed for 30 minutes to quickly cool your zone.
  • Automated Operation: Auto operation mode continually compares your zones' current and desired temperatures and uses that data to intelligently adjust fan speed and refrigerant flow to provide optimal comfort.
  • Sleep Mode: With the sleep mode and timer functions, you can set the indoor units to save energy at night. Sleep mode will incrementally adjust temperatures for an hour before the timer function automatically deactivates the units.
  • Condensate Protection: Condensate overflow can damage your indoor unit and your home. Internal condensate pumps with 27.5" of lift protect these indoor units through reliable, effective condensate removal.
  • Improved Air Quality: These mini split indoor units include anti-fungal filters to keep your air clean. These filters capture contaminants like dust and bacteria, and they are washable to ensure long term air quality.
  • Dehumidify: LG's multi-zone indoor units include a dehumidifying operation mode. In this mode, the units' internal sensors monitor temperature and modify the set point and fan speed to remove moisture from the air.

Product Assurance:

  • Certifications:
    • AHRI
    • ISO
  • Performance and Efficiency:
    • SEER: 22
    • SEER2: 21.5
    • HSPF: 10
    • HSPF2: 9
    • EER: 13
  • Manufacturer Warranty: 5 Year Limited

Required Components:

  • Line Set: Line set tubing transfers refrigerant between your outdoor condenser and indoor units
  • Drain Line: The drain line removes the condensate from your system. It connects your system to the drain location of your choosing
  • Connecting Cable: The connecting cable provides power to your indoor units from your outdoor condenser
  • Disconnect Box and Electrical Whip Kit: The disconnect box and whip kit gives an easy way to connect your outdoor condenser to your fuse box
  • Base Pan Heater (Optional): The base pan heater stops ice from building up on the outdoor unit, preventing performance degradation and potential damage
  • Outdoor Condenser Plastic Pad (Optional): An outdoor condenser pad provides an even surface on which to place your outdoor condenser
  • Wall Bracket (Optional): A wall bracket provides a way to mount your outdoor condenser off the ground to keep it clear it of debris

Recommended Components:

  • Recommended line set sizes for indoor unit connectivity:
  • LCN097HV4-NOGRILLE: 1/4" x 3/8" Line Set (Qty 4)

Specifications:


LMU363HV

Solid Brass

  • Cooling BTU Capacity: 36000
  • Heating BTU Capacity: 36000
  • Zone Capacity: 4
  • Sound Level: 54 dB
  • Low Ambient Heating: Yes
  • Minimum Outdoor Temperature for Heating: -4 F
  • Minimum Outdoor Temperature for Cooling: 14 F
  • Depth: 15-1/2"
  • Height: 32-7/8"
  • Width: 37-3/8"
  • Recommended Breaker Size: 25 A
  • Voltage: 208, 230V


PT-QAGW0 (x4)

Solid Brass

  • Type: Grilles
  • Product Category: Mini Split Air Conditioner Accessory
  • Width: 24-3/8"
  • Length: 24-3/8
  • Depth: 1-3/8"


LCN098HV4-NG (x4)

Solid Brass

  • Zone Cooling BTU: 9000
  • Zone Heating BTU: 10400
  • Cooling Area: 400 Sq. Ft.
  • Sound Level: 30 to 36 dB
  • Liquid Line Connection Size: 1/4" Inch
  • Gas Line Connection Size: 3/8" Inch
  • Depth: 22-7/16"
  • Height: 8-7/16"
  • Width: 22-7/16"
  • Voltage: 208, 230V

Dimensions and Measurements

CFM
300, 230
Cooling Area
400 sq. ft.
Depth (Condenser)
15.5 in.
Depth (Indoor Unit)
22.4375 in.
Gas Connection
3/8"
Height (Condenser)
32.844 in.
Height (Indoor Unit)
8.4375 in.
Liquid Line Connection Size
1/4"
Maximum Line Set Length
246.1 ft.
Product Weight
455.9 lbs.
Width (Condenser)
37.406 in.
Width (Indoor Unit)
22.4375 in.

Dimensions and Measurements

CFM
300, 230
Cooling Area
400 sq. ft.
Depth (Condenser)
15.5 in.
Depth (Indoor Unit)
22.4375 in.
Gas Connection
3/8"
Height (Condenser)
32.844 in.
Height (Indoor Unit)
8.4375 in.
Liquid Line Connection Size
1/4"
Maximum Line Set Length
246.1 ft.
Product Weight
455.9 lbs.
Width (Condenser)
37.406 in.
Width (Indoor Unit)
22.4375 in.

Included Components

Branch Box Required
No
Heater Included
Yes
Includes Remote
Yes
Includes Thermostat
Yes
Includes Timer
Yes
Line Set Included
No

Included Components

Branch Box Required
No
Heater Included
Yes
Includes Remote
Yes
Includes Thermostat
Yes
Includes Timer
Yes
Line Set Included
No

Characteristics and Features

Auto Restart
Yes
Control Type
Remote
Indoor Unit Type
Ceiling Cassette
Installation Type
Mini Split
Low Ambient Heating
Yes
Refrigerant
R-410A
Wireless Communication
WiFi

Characteristics and Features

Auto Restart
Yes
Control Type
Remote
Indoor Unit Type
Ceiling Cassette
Installation Type
Mini Split
Low Ambient Heating
Yes
Refrigerant
R-410A
Wireless Communication
WiFi

Electrical and Operational Information

Amperage
25
Auto Shut Off
Yes
Breaker Needs
25 Amps
Cooling BTU Capacity
36000
Cooling Power Input
2461
dBA (High)
54
dBA (Low)
30
EER
13
Electrical Phases
1
Fan Speeds
3
Frequency
60 Hertz
Heating BTU Capacity
36000
Heating Power Input
2740
Minimum Outdoor Temperature for Cooling
14 °F
Minimum Outdoor Temperature for Heating
-4 °F
Number of Zones
4
Power Source
Hardwired
Voltage
208
Zone Capacity
4
Zone Cooling BTU
9000
Zone Heating BTU
10400

Electrical and Operational Information

Amperage
25
Auto Shut Off
Yes
Breaker Needs
25 Amps
Cooling BTU Capacity
36000
Cooling Power Input
2461
dBA (High)
54
dBA (Low)
30
EER
13
Electrical Phases
1
Fan Speeds
3
Frequency
60 Hertz
Heating BTU Capacity
36000
Heating Power Input
2740
Minimum Outdoor Temperature for Cooling
14 °F
Minimum Outdoor Temperature for Heating
-4 °F
Number of Zones
4
Power Source
Hardwired
Voltage
208
Zone Capacity
4
Zone Cooling BTU
9000
Zone Heating BTU
10400

Warranty and Product Information

AHRI Reference Number
208131890
Approved for Commercial Use
Yes
Certifications
AHRI, ISO
Collection
Multi F
DOE Regional Compliance
Nationwide
Energy Star
Yes
HSPF
10
HSPF2
9
Manufacturer Warranty
5 Year Limited
SEER Cooling
22
SEER2
21.5

Warranty and Product Information

AHRI Reference Number
208131890
Approved for Commercial Use
Yes
Certifications
AHRI, ISO
Collection
Multi F
DOE Regional Compliance
Nationwide
Energy Star
Yes
HSPF
10
HSPF2
9
Manufacturer Warranty
5 Year Limited
SEER Cooling
22
SEER2
21.5

Reviews

(0)

Product Q&A

Matching Products