Skip to main content
Shipping to:Hilliard, OH
LG
N/A
Alternate Image
Alternate Image
N/A
Alternate Image
Alternate Image

LG Multi F Series 18K BTU Cooling / 22K BTU Heating 21 SEER2 Two Zone Floor Console Mini Split Package with (2) 9k BTU Indoor Units

Model: L2L18F09090000
|
Item: bci4153295

$3,970.05
1 In Stock
placeholder
Free Shipping!
Leaves the Warehouse in 2 to 5 business days
-
Return & Shipping Details

Details

Please note: Mini splits must be installed by a professional according to your local codes. Any mini split installed otherwise will void any manufacturer warranty.

For questions or assistance, please call (855) 484-3292 to speak to one of our experts.

LG continues to demonstrate global leadership in innovation and technology with their advancements in home comfort solutions. The LGRED° Heat ductless heat pump system boasts superior heating performance in extreme cold weather climates. The powerful LMU180HHV outdoor condenser works with LG indoor units to provide the maximum amount of comfort control for your home. With several air flow options, quiet operation, and weather protection technology, the LGRED° Heat system is accommodating to nearly every home.

Features:

  • The LG low wall console units use a dual filtration system to keep your air clean. A washable filter is backed up by a plasma filtration system that can attract and capture microscopic irritants for pristine air quality.
  • When the hot start function is enabled, the outdoor unit's fan will not engage until the outdoor condenser has had the opportunity to warm the indoor coil. This prevents the unit from blowing cold air during heating operations.

Special Features:

  • Integrated Base Pan Heater: Base pan heaters come factory installed on all LGRED° outdoor condensers in order to mitigate the risk of damage caused by freezing condensate.
  • Inverter Technology: LG's inverter technology features an electronic expansion valve and a variable speed compressor that carefully regulates refrigerant flow, reducing energy consumption and providing consistent, accurate temperatures without overshooting or short-cycling.
  • Gold Fin Protection: To ensure the reliability and longevity of the LMU180HHV's heat exchanger, LG employs a Gold Fin coating that prevents corrosion and improves durability.
  • Quiet Design: Thanks to a brushless direct current fan motor, both the outdoor and indoor units in this system produce less mechanical and electrical noise, allowing them to provide comfort that doesn't disrupt your home.
  • Air Flow Options: This unit gives you two options for automating air flow. In swing mode, the unit will rotate through all four air flow directions. With the Chaos Wind feature, the unit cycles both air flow direction and fan speed.
  • Self-Cleaning Coil: These wall mount units feature a self-cleaning heat exchanger coil that automatically removes dirt and moisture. This helps to prevent unpleasant odors and to combat the formation of mold.
  • Jet Temperature Control: Getting your zone comfortable quickly is no problem thanks to the Jet Heat and Jet Cool modes. With the press of a button, your system will temporarily adjust the set point and fan speed to provide rapid heating or cooling.
  • Automated Operation: Auto operation mode continually compares your zone's current and desired temperatures and uses that data to intelligently adjust the unit's fan speed and refrigerant flow to provide optimal comfort.
  • Sleep Mode: With the sleep mode and timer functions, you can set this indoor unit to save energy at night. Sleep mode will incrementally adjust temperature for an hour before the timer function automatically deactivates the unit.
  • Dehumidify: LG's multi-zone indoor units include a dehumidifying operation mode. In this mode, the unit's internal sensors monitor temperature and modify the set point and fan speed to remove moisture from the air.

Product Assurance:

  • Certifications:
    • AHRI
    • ETL
  • Performance and Efficiency:
    • SEER: 21
    • SEER2: 21
    • HSPF: 10
    • HSPF2: 9.2
    • EER: 13.5
  • Manufacturer Warranty: 5 Year Limited

Required Components:

  • Line Set: Line set tubing transfers refrigerant between your outdoor condenser and indoor units
  • Drain Line: The drain line removes the condensate from your system. It connects your system to the drain location of your choosing
  • Connecting Cable: The connecting cable provides power to your indoor units from your outdoor condenser
  • Branch Box: The branch box connects to the condenser and allows for multiple refrigerant lines to be connected to your indoor evaporators
  • Disconnect Box and Electrical Whip Kit: The disconnect box and whip kit gives an easy way to connect your outdoor condenser to your fuse box
  • Base Pan Heater (Optional): The base pan heater stops ice from building up on the outdoor unit, preventing performance degradation and potential damage
  • Outdoor Condenser Plastic Pad (Optional): An outdoor condenser pad provides an even surface on which to place your outdoor condenser
  • Wall Bracket (Optional): A wall bracket provides a way to mount your outdoor condenser off the ground to keep it clear it of debris

Recommended Components:

  • Recommended line set sizes for indoor unit connectivity:
  • LQN090HV4: 1/4" x 3/8" Line Set (Qty 2)

Specifications:


LMU180HHV

Solid Brass

  • Cooling BTU Capacity: 18000
  • Heating BTU Capacity: 22000
  • Zone Capacity: 2
  • Cooling Area: 1000 Sq. Ft.
  • Sound Level: 54 dB
  • Low Ambient Heating: Yes
  • Minimum Outdoor Temperature for Heating: -13 F
  • Minimum Outdoor Temperature for Cooling: 14 F
  • Depth: 13"
  • Height: 32-7/8"
  • Width: 37-3/8"
  • Recommended Breaker Size: 25 A
  • Amperage: 18.6 A
  • Voltage: 208, 230V


LQN090HV4 (x2)

Solid Brass

  • Zone Cooling BTU: 9000
  • Zone Heating BTU: 11000
  • Cooling Area: 400 Sq. Ft.
  • Sound Level: 27 to 38 dB
  • Liquid Line Connection Size: 1/4" Inch
  • Gas Line Connection Size: 3/8" Inch
  • Depth: 8-1/4"
  • Height: 23-5/8"
  • Width: 27-9/16"
  • Voltage: 208, 230V

Dimensions and Measurements

CFM
304, 177
Cooling Area
1000, 400 sq. ft.
Depth (Condenser)
13 in.
Depth (Indoor Unit)
8.281 in.
Gas Connection
3/8"
Height (Condenser)
32.84375 in.
Height (Indoor Unit)
23.625 in.
Liquid Line Connection Size
1/4"
Maximum Line Set Length
164 ft.
Product Weight
403.7 lbs.
Width (Condenser)
37.40625 in.
Width (Indoor Unit)
27.563 in.

Dimensions and Measurements

CFM
304, 177
Cooling Area
1000, 400 sq. ft.
Depth (Condenser)
13 in.
Depth (Indoor Unit)
8.281 in.
Gas Connection
3/8"
Height (Condenser)
32.84375 in.
Height (Indoor Unit)
23.625 in.
Liquid Line Connection Size
1/4"
Maximum Line Set Length
164 ft.
Product Weight
403.7 lbs.
Width (Condenser)
37.40625 in.
Width (Indoor Unit)
27.563 in.

Included Components

Base Pan Heater Included
Yes
Branch Box Required
Yes
Heater Included
Yes
Includes Remote
Yes
Includes Thermostat
Yes
Includes Timer
Yes
Line Set Included
No

Included Components

Base Pan Heater Included
Yes
Branch Box Required
Yes
Heater Included
Yes
Includes Remote
Yes
Includes Thermostat
Yes
Includes Timer
Yes
Line Set Included
No

Characteristics and Features

Auto Restart
Yes
Control Type
Remote
Indoor Unit Type
Floor Console
Installation Type
Mini Split
Low Ambient Heating
Yes
Refrigerant
R-410A
Wireless Communication
WiFi

Characteristics and Features

Auto Restart
Yes
Control Type
Remote
Indoor Unit Type
Floor Console
Installation Type
Mini Split
Low Ambient Heating
Yes
Refrigerant
R-410A
Wireless Communication
WiFi

Electrical and Operational Information

Amperage
18.6
Auto Shut Off
Yes
Breaker Needs
25 Amps
Cooling BTU Capacity
18000
Cooling Power Input
1330
dBA (High)
54
dBA (Low)
27
EER
13.5
Electrical Phases
1
Fan Speeds
4
Frequency
60 Hertz
Heating BTU Capacity
22000
Heating Power Input
2220
Minimum Outdoor Temperature for Cooling
14 °F
Minimum Outdoor Temperature for Heating
-13 °F
Number of Zones
2
Power Source
Hardwired
Voltage
208
Zone Capacity
2
Zone Cooling BTU
9000
Zone Heating BTU
11000

Electrical and Operational Information

Amperage
18.6
Auto Shut Off
Yes
Breaker Needs
25 Amps
Cooling BTU Capacity
18000
Cooling Power Input
1330
dBA (High)
54
dBA (Low)
27
EER
13.5
Electrical Phases
1
Fan Speeds
4
Frequency
60 Hertz
Heating BTU Capacity
22000
Heating Power Input
2220
Minimum Outdoor Temperature for Cooling
14 °F
Minimum Outdoor Temperature for Heating
-13 °F
Number of Zones
2
Power Source
Hardwired
Voltage
208
Zone Capacity
2
Zone Cooling BTU
9000
Zone Heating BTU
11000

Warranty and Product Information

AHRI Reference Number
10445372
Approved for Commercial Use
Yes
Certifications
AHRI, ETL
Collection
LGRED Heat, Multi F
DOE Regional Compliance
Nationwide
Energy Star
Yes
HSPF
10
HSPF2
9.2
Manufacturer Warranty
5 Year Limited
SEER Cooling
21
SEER2
21

Warranty and Product Information

AHRI Reference Number
10445372
Approved for Commercial Use
Yes
Certifications
AHRI, ETL
Collection
LGRED Heat, Multi F
DOE Regional Compliance
Nationwide
Energy Star
Yes
HSPF
10
HSPF2
9.2
Manufacturer Warranty
5 Year Limited
SEER Cooling
21
SEER2
21

Reviews

(0)

Product Q&A

Matching Products