Skip to main content
Shipping to:Hilliard, OH
Durastar
White
Alternate Image
Alternate Image
Alternate Image
Alternate Image
Alternate Image
Alternate Image
Alternate Image
Alternate Image
White
Alternate Image
Alternate Image
Alternate Image
Alternate Image
Alternate Image
Alternate Image
Alternate Image
Alternate Image

Durastar 18K BTU Cooling / 19K BTU Heating 21 SEER2 Two Zone Wall Mount Mini Split Package with (2) 9k BTU Indoor Units

Model: DR2H18W0909
|
Item: bci4207283

$3,123.79
Finish: White -
806 In Stock
placeholder
Free Shipping!
Leaves the Warehouse Today, December 26th
-
Return & Shipping Details

Details

 

Please note: Mini splits must be installed by a professional according to your local codes. Any mini split installed otherwise will void any manufacturer warranty.

 

For questions or assistance, please call (855) 484-3292 to speak to one of our experts.

Engineered for comfort, Durastar is backed by resilient technology and will withstand the test of time and nature's elements. Providing energy efficient, value-friendly HVAC equipment for every space, Durastar creates a comfortable environment for any homeowner. Durastar mini-splits are ideal for renovations, remodels and zone-specific heating and cooling needs.

Special Features:

  • Sirius Heat™ Low Ambient Operations: This outdoor unit supports cooling operations down to 5 degrees Fahrenheit, heating operations down to -22 degrees Fahrenheit and provides up to 100% heating capacity at 0 degrees
  • Wireless Remote Control With "Follow Me" Technology: This function uses the temperature at the remote's location, instead of the indoor unit's location, to optimize the temperature around you and ensure maximum comfort
  • Auto Restart: The indoor unit has an auto-restart module that allows the unit to restart automatically and, in the case of a sudden power failure, will restore those setting automatically after power returns
  • 24-Hour Timer Feature: The timer function establishes the amount of time that will elapse before the unit will automatically turn on/off
  • Third-Party Thermostat Interface: The DR24VINT1 interface works with Durastar indoor units, enabling third-party Wi-Fi compatible thermostats to control them. It's compatible with various 24V Wi-Fi thermostat brands like Nest, Ecobee, Honeywell, and Proselect for wireless control.

Product Assurance:

  • Certifications:
    • AHRI
    • ETL
  • Performance and Efficiency:
    • SEER: 22.8
    • SEER2: 21
    • HSPF: 10.6
    • HSPF2: 10.2
    • EER: 14.7
  • Manufacturer Warranty: 10 Year Parts

Required Components:

  • Line Set: Line set tubing transfers refrigerant between your outdoor condenser and indoor units
  • Drain Line: The drain line removes the condensate from your system. It connects your system to the drain location of your choosing
  • Connecting Cable: The connecting cable provides power to your indoor units from your outdoor condenser
  • Disconnect Box and Electrical Whip Kit: The disconnect box and whip kit gives an easy way to connect your outdoor condenser to your fuse box
  • Base Pan Heater: The base pan heater stops ice from building up on the outdoor unit, preventing performance degradation and potential damage
  • Outdoor Condenser Plastic Pad (Optional): An outdoor condenser pad provides an even surface on which to place your outdoor condenser
  • Wall Bracket (Optional): A wall bracket provides a way to mount your outdoor condenser off the ground to keep it clear it of debris

Package Component Specifications:


DRAW09F1B (x2)

Solid Brass

  • Zone Cooling BTU: 9000
  • Zone Heating BTU: 10000
  • Cooling Area: 350 Sq. Ft.
  • Sound Level: 24 to 40 dB
  • Liquid Line Connection Size: 1/4" Inch
  • Gas Line Connection Size: 3/8" Inch
  • Depth: 7-7/8"
  • Height: 11-5/8"
  • Width: 31-9/16"
  • Recommended Breaker Size: 15 A
  • Amperage: 15 A
  • Voltage: 208, 230V


DRA2U18M1B

Solid Brass

  • Cooling BTU Capacity: 18000
  • Heating BTU Capacity: 19000
  • Zone Capacity: 2
  • Cooling Area: 850 Sq. Ft.
  • Sound Level: 58.5 dB
  • Minimum Outdoor Temperature for Heating: -13 F
  • Minimum Outdoor Temperature for Cooling: 5 F
  • Depth: 13-7/16"
  • Height: 26-1/2"
  • Width: 35-1/16"
  • Recommended Breaker Size: 25 A
  • Voltage: 208, 230V

Additional Durastar Links

Dimensions and Measurements

CFM
1765, 153
Cooling Area
350, 850 sq. ft.
Depth (Condenser)
13.4375 in.
Depth (Indoor Unit)
7.875 in.
Gas Connection
3/8"
Height (Condenser)
26.5 in.
Height (Indoor Unit)
11.625 in.
Liquid Line Connection Size
1/4"
Maximum Line Set Length
131 ft.
Moisture Removal (Pints per Hour)
37.2
Product Weight
105.8, 18.5 lbs.
Width (Condenser)
35.0625 in.
Width (Indoor Unit)
31.5625 in.

Dimensions and Measurements

CFM
1765, 153
Cooling Area
350, 850 sq. ft.
Depth (Condenser)
13.4375 in.
Depth (Indoor Unit)
7.875 in.
Gas Connection
3/8"
Height (Condenser)
26.5 in.
Height (Indoor Unit)
11.625 in.
Liquid Line Connection Size
1/4"
Maximum Line Set Length
131 ft.
Moisture Removal (Pints per Hour)
37.2
Product Weight
105.8, 18.5 lbs.
Width (Condenser)
35.0625 in.
Width (Indoor Unit)
31.5625 in.

Included Components

Base Pan Heater Included
Yes
Branch Box Required
No
Heater Included
Yes
Includes Remote
Yes
Includes Thermostat
No
Includes Timer
Yes
Line Set Included
No

Included Components

Base Pan Heater Included
Yes
Branch Box Required
No
Heater Included
Yes
Includes Remote
Yes
Includes Thermostat
No
Includes Timer
Yes
Line Set Included
No

Characteristics and Features

Auto Restart
Yes
Control Type
Remote
Indoor Unit Type
Wall Mount
Installation Type
Mini Split
Low Ambient Heating
Yes
Refrigerant
R-410A
Sleep Mode
Yes

Characteristics and Features

Auto Restart
Yes
Control Type
Remote
Indoor Unit Type
Wall Mount
Installation Type
Mini Split
Low Ambient Heating
Yes
Refrigerant
R-410A
Sleep Mode
Yes

Electrical and Operational Information

Amperage
15, 25
Breaker Needs
15, 25 Amps
Cooling BTU Capacity
18000
dBA (High)
58.5
dBA (Low)
24
EER
12.5, 14.7
Electrical Phases
1
Fan Speeds
3
Frequency
60 Hertz
Heating BTU Capacity
19000
Minimum Outdoor Temperature for Cooling
5 °F
Minimum Outdoor Temperature for Heating
-13 °F
Number of Zones
2
Power Source
Hardwired
Voltage
208, 230
Zone Capacity
2
Zone Cooling BTU
9000
Zone Heating BTU
10000

Electrical and Operational Information

Amperage
15, 25
Breaker Needs
15, 25 Amps
Cooling BTU Capacity
18000
dBA (High)
58.5
dBA (Low)
24
EER
12.5, 14.7
Electrical Phases
1
Fan Speeds
3
Frequency
60 Hertz
Heating BTU Capacity
19000
Minimum Outdoor Temperature for Cooling
5 °F
Minimum Outdoor Temperature for Heating
-13 °F
Number of Zones
2
Power Source
Hardwired
Voltage
208, 230
Zone Capacity
2
Zone Cooling BTU
9000
Zone Heating BTU
10000

Warranty and Product Information

AHRI Reference Number
207787171
Certifications
AHRI, ETL
Collection
Durastar
DOE Regional Compliance
Nationwide
Energy Star
Yes
HSPF
10.15, 10.6
HSPF2
10.2
Manufacturer Warranty
10 Year Parts
SEER Cooling
21.3, 21.5, 22.8
SEER2
21

Warranty and Product Information

AHRI Reference Number
207787171
Certifications
AHRI, ETL
Collection
Durastar
DOE Regional Compliance
Nationwide
Energy Star
Yes
HSPF
10.15, 10.6
HSPF2
10.2
Manufacturer Warranty
10 Year Parts
SEER Cooling
21.3, 21.5, 22.8
SEER2
21

Reviews

(0)

Product Q&A

Matching Products